Vendor:Juniper
Juniper QFX5200-32C-AFO | 32x 40/100G QSFP+/QSFP28; PoE: none; uplinks: n/a (all ports 40/100G); license: hardware-only; dual AC PSUs; airflow: front-to-back
High‑density 40/100G data center switch with 32 QSFP+/QSFP28 ports, redundant hot‑swap fans, and dual AC power supplies with front‑to‑back airflow. Ideal for leaf/spine fabrics where every port can serve as data or fabric connectivity. Hardware only; software services sold separately. -
Vendor:Juniper
Juniper QFX5200-32C-AFI | Switch | 32x100G QSFP28 (40G compatible; breakout 4x25G/4x10G) | Non‑PoE | Uplinks: up to 32x100G | Hardware‑only (software services sold separately) | 2x AC PSU | Back‑to‑front airflow
High‑performance 1RU data center switch with 32 QSFP28 ports for flexible 100G/40G connectivity and breakout to 4x25G or 4x10G. Includes redundant hot‑swap fans and dual AC power supplies with back‑to‑front airflow for cold‑aisle alignment. Hardware‑only model; software services and subscriptions are sold separately. -
Vendor:Juniper
Juniper QFX5130E-32CD-D-AO | 32x 400G QSFP-DD, 1U, DC PSU, AFO airflow (front-to-back)
QFX5130E-32CD-D-AO
Vendor:JuniperJuniper QFX5130E-32CD-D-AO | 32x 400G QSFP-DD, 1U, DC PSU, AFO airflow (front-to-back)
High-density 32-port 400GbE QSFP-DD 1U data center switch with DC power and AFO (front-to-back) airflow for hot-aisle deployments. Ideal for spine/leaf fabrics and high-throughput aggregation. Compatible with a wide range of 100/200/400G optics and DACs. -
Vendor:Juniper
Juniper QFX5130E-32CD-D-AI | 32x 400G QSFP-DD, 1U DC, AFI back-to-front airflow, non-PoE, 12.8Tbps
QFX5130E-32CD-D-AI
Vendor:JuniperJuniper QFX5130E-32CD-D-AI | 32x 400G QSFP-DD, 1U DC, AFI back-to-front airflow, non-PoE, 12.8Tbps
High-density 400GbE fixed data center switch with 32 QSFP-DD ports in a compact 1U form factor. This DC-powered, AFI (back-to-front) airflow variant suits rear cold-aisle deployments and facilities with DC plant power. Provides up to 12.8 Tbps switching capacity with hot-swappable fan and power modules for continuous operation. -
Vendor:Juniper
Juniper QFX5130E-32CD-AFO | 32x400G QSFP-DD, PoE: None, Uplinks: 32x400G, License: Base, 1U, AC PSU, Airflow: Front-to-Back (AFO)
QFX5130E-32CD-AFO
Vendor:JuniperJuniper QFX5130E-32CD-AFO | 32x400G QSFP-DD, PoE: None, Uplinks: 32x400G, License: Base, 1U, AC PSU, Airflow: Front-to-Back (AFO)
Ultra-high-density 400G 1U data center switch with 32x 400G QSFP-DD ports for modern spine/leaf designs and high-throughput interconnects. AFO airflow (front-to-back) fits hot-aisle containment, and AC power eases deployment in standard racks. Ideal for EVPN-VXLAN fabrics that require massive scale and performance. -
Vendor:Juniper
Juniper QFX5130E-32CD-AFI | 32x400G QSFP-DD, PoE: None, Uplinks: 32x400G, License: Base, 1U, AC PSU, Airflow: Back-to-Front (AFI)
QFX5130E-32CD-AFI
Vendor:JuniperJuniper QFX5130E-32CD-AFI | 32x400G QSFP-DD, PoE: None, Uplinks: 32x400G, License: Base, 1U, AC PSU, Airflow: Back-to-Front (AFI)
Ultra-high-density 400G 1U data center switch with 32x 400G QSFP-DD ports for leaf/spine fabrics and scale-out interconnects. AFI airflow (back-to-front) supports rear intake environments, while AC power simplifies facility integration. Built for EVPN-VXLAN deployments requiring maximum port scalability and throughput. -
Vendor:Juniper
Juniper QFX5130-48CM-D-AFO | 48x100G + 8x400G, MACsec, 1U, AFO airflow, DC PSU, QSFP28 + QSFP-DD
QFX5130-48CM-D-AFO
Vendor:JuniperJuniper QFX5130-48CM-D-AFO | 48x100G + 8x400G, MACsec, 1U, AFO airflow, DC PSU, QSFP28 + QSFP-DD
1U 100/400GbE data center switch with 48x100G access ports and 8x400G uplinks for scalable leaf/spine fabrics. Delivers hardware MACsec, dual hot-swappable DC power supplies, and AFO airflow (front-to-back) for cold-aisle to hot-aisle data center layouts. -
Vendor:Juniper
Juniper QFX5130-48CM-D-AFI | 48x100G + 8x400G, MACsec, 1U, AFI airflow, DC PSU, QSFP28 + QSFP-DD
QFX5130-48CM-D-AFI
Vendor:JuniperJuniper QFX5130-48CM-D-AFI | 48x100G + 8x400G, MACsec, 1U, AFI airflow, DC PSU, QSFP28 + QSFP-DD
High-density 100/400GbE data center switch with 48x100G access and 8x400G uplinks, optimized for EVPN-VXLAN leaf/spine fabrics. Features hardware MACsec, dual hot-swappable DC power supplies, and AFI airflow (back-to-front) for hot-aisle to cold-aisle cooling schemes. -
Vendor:Juniper
Juniper QFX5130-48CM-AFO | 48x100G + 8x400G | 1U AC | MACsec | AFO front-to-back airflow | 8x400G uplinks
QFX5130-48CM-AFO
Vendor:JuniperJuniper QFX5130-48CM-AFO | 48x100G + 8x400G | 1U AC | MACsec | AFO front-to-back airflow | 8x400G uplinks
High-density 100/400G data center switch built for scalable EVPN-VXLAN fabrics. AFO (front-to-back) airflow aligns with front-cold aisle deployments. Features redundant, hot-swappable AC power supplies and fans plus MACsec capabilities for secure connectivity. -
Vendor:Juniper
Juniper QFX5130-48CM-AFI | 48x100G + 8x400G | 1U AC | MACsec | AFI back-to-front airflow | 8x400G uplinks
QFX5130-48CM-AFI
Vendor:JuniperJuniper QFX5130-48CM-AFI | 48x100G + 8x400G | 1U AC | MACsec | AFI back-to-front airflow | 8x400G uplinks
High-density 100/400G data center switch for EVPN-VXLAN leaf/spine fabrics with MACsec capabilities. AFI (back-to-front) airflow aligns with deployments requiring port-side exhaust. Dual hot-swappable AC power supplies and redundant fans provide resilient operation. -
Vendor:Juniper
Juniper QFX5130-48C-DC-AFO | 48x 100G QSFP28 + 8x 400G QSFP-DD, uplinks 8x400G, non-PoE, 1U, DC power, airflow AFO (front-to-back), Trident 4 ASIC
High-density 1U data center switch delivering 48x 100GbE and 8x 400GbE with DC power and AFO front-to-back airflow. Suited for leaf/spine or aggregation roles, it supports flexible breakouts and advanced L2/L3 with EVPN-VXLAN under Junos OS. -
Vendor:Juniper
Juniper QFX5130-48C-DC-AFI | 48x 100G QSFP28 + 8x 400G QSFP-DD, uplinks 8x400G, non-PoE, 1U, DC power, airflow AFI (back-to-front), Trident 4 ASIC
High-density 1U data center switch delivering 48x 100GbE and 8x 400GbE with DC power and AFI back-to-front airflow. Ideal for spine/leaf or edge aggregation, with flexible breakouts and rich L2/L3 and EVPN-VXLAN capabilities under Junos OS. -
Vendor:Juniper
Juniper QFX5130-48C-AFO | JUNIPER QFX5130 48C AFO: 48x100G+8X400G 1U AC ports AFO AIR OUT (AFO) front to back (air exhausts through the back of the switch)
QFX5130 48C AFO: 48x100G+8X400G 1U AC ports AFO AIR OUT (AFO) front to back ( -
Vendor:Juniper
Juniper QFX5130-48C-AFI | JUNIPER QFX5130 48C AFI: 48x100G+8X400G 1U AC ports AFI AIR IN (AFI) back to front (air enters through the back of the switch)
QFX5130 48C AFI: 48x100G+8X400G 1U AC ports AFI AIR IN (AFI) back to front (a -
Vendor:Juniper
Juniper QFX5130-32CD-AFO | 32x400G QSFP-DD, 1U, AFO (port intake/PSU exhaust), non-PoE
QFX5130-32CD-AFO
Vendor:JuniperJuniper QFX5130-32CD-AFO | 32x400G QSFP-DD, 1U, AFO (port intake/PSU exhaust), non-PoE
High-density 1U 400G switch with 32 QSFP-DD ports and AFO airflow (port-side intake to PSU-side exhaust) for reversed data center cooling schemes. Suited for spine/leaf fabrics with optional 100G breakouts on Junos OS. -
Vendor:Juniper
Juniper QFX5130-32CD-AFI | 32x400G QSFP-DD, 1U, AFI (PSU intake/port exhaust), non-PoE
QFX5130-32CD-AFI
Vendor:JuniperJuniper QFX5130-32CD-AFI | 32x400G QSFP-DD, 1U, AFI (PSU intake/port exhaust), non-PoE
High-density 1U 400G data center switch with 32 QSFP-DD ports and AFI airflow (PSU-side intake to port-side exhaust) for hot-aisle/cold-aisle alignment. Flexible breakout options enable 100G aggregation in leaf/spine designs running Junos OS.
Why Choose XS Network Tech?
We are a trusted partner for businesses of all sizes, including government departments, data centres, and service providers. Our expert team in sales, logistics, and customer service ensures that your needs are met with speed and precision, from pre-sales consultation to order fulfilment. With a commitment to fast delivery, sustainability, and a wide inventory, XS Network Tech is your go-to source for IT hardware. Trust us for quality, fast responses, and a hassle-free experience every time.