The Arista 7050SX3-48YC8C is a 1RU data centre leaf switch from the 7050X3 Series, built for top-of-rack deployments with 25G server and storage connectivity. This -DC-F variant uses DC power supplies and front-to-rear airflow, which suits telco and carrier sites running -48 VDC as well as enterprise and cloud environments moving from 10G to 25G.

It provides 48 SFP25 ports that run at 25G, 10G or 1G, plus 8 QSFP100 ports for 100G or 40G uplinks, with breakout support to 4x25G or 4x10G. Rated throughput is 2 (4) Tbps with a 1 Bpps forwarding rate, 800 ns latency and a 32 MB dynamic packet buffer. Power comes from two hot-swappable 500 W DC supplies (PWR-511-DC) in a 1+1 redundant arrangement, taking -48 to -60 VDC input. Typical draw is 119 W, with a 290 W maximum. The switch has 16 GB of system memory and 32 GB of flash, and runs Arista EOS with the LIC-FIX-2 feature licence group.

The QSFP100 ports accept 100G and 40G optics and cables, while the SFP25 ports accept 25G, 10G and 1G modules. The fan tray is FAN-7011M-F/R, and NEBS deployments use the KIT-GND-EXT-1RU grounding kit.

Enquire with XS Network Tech for new or used pricing and availability.

Features

- Wire-speed Layer 2 and Layer 3 forwarding with 128-way ECMP
- Unified Forwarding Table with 288K MAC entries and 360K IPv4 routes
- Multi-chassis LAG for active/active Layer 2 multi-pathing
- Arista EOS with Stateful Fault Repair, live software patching and Smart System Upgrade
- VXLAN, VM Tracer, OpenFlow, DirectFlow and eAPI support
- CloudVision, Zero Touch Provisioning, LANZ microburst detection and sFlow
- Hot-swap 1+1 power supplies and N+1 fans with colour-coded identification
- Tool-less rails for rack installation

Warranty

All products sold by XS Network Tech include a 12-month warranty on both new and used items. Our in-house technical team thoroughly tests used hardware prior to sale to ensure enterprise-grade reliability.

All technical data should be verified on the manufacturer data sheets.

View full details

specs-tabs

Collapsible content

Technical Specifications

FAQs

Technical Specifications

- Ports: 48x SFP25 (25G, 10G or 1G) and 8x QSFP100 (100G or 40G)
- Breakout: QSFP100 supports 4x25G and 4x10G
- Throughput: 2 (4) Tbps
- Forwarding rate: 1 Bpps
- Latency: 800 ns
- Packet buffer: 32 MB, dynamic allocation
- CPU: Quad-Core x86
- System memory: 16 GB
- Flash storage: 32 GB
- Management ports: 1 management, 1 RS-232 serial (RJ-45), 1 USB
- Power supplies: 2x hot-swap PWR-511-DC, 1+1 redundant
- DC input voltage: -48 to -60 VDC
- PSU output power: 500 W each
- Typical and maximum power: 119 W / 290 W (typical measured at 25 C, 50% load, excludes transceivers)
- Fans: 4 hot-swappable, N+1 redundant (FAN-7011M-F/R)
- Airflow: front-to-rear
- Form factor: 1RU
- Dimensions (WxHxD): 44 x 4.4 x 46.8 cm (17.3 x 1.75 x 18.4 in)
- Weight: 9.45 kg (21 lbs)
- Operating temperature: 0 to 40 C
- Storage temperature: -40 to 70 C
- Relative humidity: 5 to 90%
- Operating altitude: 0 to 3,000 m
- Minimum EOS: 4.30.1

FAQs

Q: Which licence does this switch use?
A: It runs Arista EOS and uses the LIC-FIX-2 feature licence group. Optional add-on licences include LIC-FIX-2-E for Enhanced L3, LIC-FIX-2-V for Virtualization and LIC-FIX-2-Z for Monitoring and Automation.

Q: What power input does the DC model need?
A: It takes -48 to -60 VDC through two hot-swap PWR-511-DC supplies rated at 500 W each, in a 1+1 redundant arrangement. DC wiring uses 10-12 AWG cable with lugs.

Q: What optics and cables work with the ports?
A: The 8 QSFP100 ports support 100G and 40G optics and cables, plus 4x10G and 4x25G breakout cables. The 48 SFP25 ports support 25G, 10G and 1G modules, including SR, LR, CR and AOC types.

Q: What airflow does this variant use?
A: This -F variant uses front-to-rear airflow. It pairs with fan tray FAN-7011M-F/R, and the DC power supplies are PWR-511-DC.

Q: Does it need a grounding kit for NEBS deployments?
A: NEBS-compliant deployments require chassis grounding, which uses the KIT-GND-EXT-1RU grounding kit.

Recently Viewed

  • Request a Quote

    Looking for competitive pricing? Submit a request, and our team will provide a tailored quote that fits your needs.

  • Contact Us Directly

    Have a question or need immediate assistance? Call us for expert advice and real-time support.

    Call us Now  
  • Contact Us Directly

    Have a question or need immediate assistance? Call us for expert advice and real-time support.

    Contact us