Vendor:Cisco
Cisco 15454-M-FILLER | M6/M2 line-slot filler card | detectable blank | airflow + EMI shield
15454-M-FILLER
Stock Status: Enquire
Vendor:CiscoCisco 15454-M-FILLER | M6/M2 line-slot filler card | detectable blank | airflow + EMI shield
Detectable line-slot filler card that preserves designed airflow, maintains EMI shielding, and prevents dust ingress when a line slot is unused on M-Series optical shelves. The shelf can register its presence for proper inventory and alarm behavior. -
Vendor:Cisco
Cisco 15454-FTF4 | Fan Tray Filter | FTA3 & CC FTA | ANSI | Airflow Dust Filter
15454-FTF4
Stock Status: Enquire
Vendor:CiscoCisco 15454-FTF4 | Fan Tray Filter | FTA3 & CC FTA | ANSI | Airflow Dust Filter
Replacement airflow filter for FTA3 and CC FTA fan trays used in 15454 platform shelves. ANSI-compliant fitment helps maintain cooling performance by reducing dust ingress and is designed for quick field replacement and routine maintenance. -
Vendor:Cisco
Cisco 15454-FTF2 | Fan tray air filter | ONS 15454 shelves | NEBS3/NEBS3E/ANSI | quick-replace
15454-FTF2
Stock Status: Enquire
Vendor:CiscoCisco 15454-FTF2 | Fan tray air filter | ONS 15454 shelves | NEBS3/NEBS3E/ANSI | quick-replace
Replace the ONS 15454 fan tray air filter to restore proper airflow and help protect optics and electronics from dust accumulation. Tool-less, front-access service supports routine maintenance and sustained cooling performance. -
Vendor:Cisco
Cisco 15454-FILLER | Detectable blank filler panel | ONS 15454 shelves | airflow cover | FRU
15454-FILLER
Stock Status: Enquire
Vendor:CiscoCisco 15454-FILLER | Detectable blank filler panel | ONS 15454 shelves | airflow cover | FRU
Close unused ONS 15454 slots with a high-visibility filler panel to preserve airflow and reduce dust ingress. Aids technicians in quickly identifying protected bays while maintaining EMI shielding and thermal performance. -
Vendor:Cisco
Cisco 15216-OSC-PTP | Passive OSC PTP coupler/filter | 1510/1514/1518 nm | ITU‑T compliant | LC | point‑to‑point supervisory channel
15216-OSC-PTP
Stock Status: Enquire
Vendor:CiscoCisco 15216-OSC-PTP | Passive OSC PTP coupler/filter | 1510/1514/1518 nm | ITU‑T compliant | LC | point‑to‑point supervisory channel
Passive optical supervisory channel (OSC) point‑to‑point coupler/filter that inserts/extracts OSC wavelengths at 1510/1514/1518 nm for out‑of‑band management and monitoring. Designed for transparent operation alongside DWDM traffic without impacting in‑band services. LC interfaces support quick field deployment in P2P topologies. -
Vendor:Cisco
Cisco 15216-MD48-CME2 | DWDM coupler/splitter plug‑in | 1×2 dual output | C‑band wideband | LC | passive module for 48‑ch systems
15216-MD48-CME2
Stock Status: Enquire
Vendor:CiscoCisco 15216-MD48-CME2 | DWDM coupler/splitter plug‑in | 1×2 dual output | C‑band wideband | LC | passive module for 48‑ch systems
Passive DWDM coupler/splitter plug‑in module for 48‑channel DWDM systems, providing a 1×2 optical split for dual output paths. Wideband C‑band operation supports monitoring, protection, or signal distribution without impacting protocol or data rate. LC connectivity enables straightforward integration into existing ODN shelves. -
Vendor:Cisco
Cisco 15216-MD-48-ODDE | DWDM mux/demux | 48ch odd | 100 GHz C‑band extended | ITU‑T G.694.1 | LC | passive rack patch panel
15216-MD-48-ODDE
Stock Status: Enquire
Vendor:CiscoCisco 15216-MD-48-ODDE | DWDM mux/demux | 48ch odd | 100 GHz C‑band extended | ITU‑T G.694.1 | LC | passive rack patch panel
48‑channel passive DWDM mux/demux patch panel for odd ITU‑T 100 GHz grid channels across the extended C‑band. Protocol‑agnostic design supports multi‑rate wavelengths from 1G to 400G and beyond, enabling scalable metro/long‑haul transport. LC connectivity and rack‑mount patch panel format simplify integration into existing ODN/DWDM shelves and frames. -
Vendor:Cisco
Cisco 15216-MD-48-ODD | DWDM 48-ch Mux/Demux patch panel (odd channels), C-band, 100 GHz ITU-T grid, exposed faceplate, passive
15216-MD-48-ODD
Stock Status: Enquire
Vendor:CiscoCisco 15216-MD-48-ODD | DWDM 48-ch Mux/Demux patch panel (odd channels), C-band, 100 GHz ITU-T grid, exposed faceplate, passive
48-channel DWDM multiplexer/demultiplexer exposed-faceplate patch panel providing the odd ITU-T channel set across the C-band with 100 GHz spacing. Passive design makes it a robust, power-free option for dense wavelength aggregation in ONS 15216 optical networks. -
Vendor:Cisco
Cisco 15216-MD-48-EVENE | DWDM 48-ch Mux/Demux patch panel (even channels, extended bandwidth), 100 GHz ITU-T grid, exposed faceplate, passive
15216-MD-48-EVENE
Stock Status: Enquire
Vendor:CiscoCisco 15216-MD-48-EVENE | DWDM 48-ch Mux/Demux patch panel (even channels, extended bandwidth), 100 GHz ITU-T grid, exposed faceplate, passive
48-channel DWDM Mux/Demux exposed-faceplate patch panel delivering the even ITU-T channel set with an extended bandwidth variant for broader passband coverage across the C-band. Designed for flexible ONS 15216 deployments where maximum wavelength utilization is required. Passive optical design for dependable operation without power. -
Vendor:Cisco
Cisco 15216-MD-48-EVEN | DWDM 48-ch Mux/Demux patch panel (even channels), C-band, 100 GHz ITU-T grid, exposed faceplate, passive
15216-MD-48-EVEN
Stock Status: Enquire
Vendor:CiscoCisco 15216-MD-48-EVEN | DWDM 48-ch Mux/Demux patch panel (even channels), C-band, 100 GHz ITU-T grid, exposed faceplate, passive
48-channel DWDM Mux/Demux patch panel with exposed faceplate for straightforward front access and cable management. Provides the even ITU-T channel set across the C-band with 100 GHz spacing. Passive optical design is ideal for space-efficient, scalable wavelength aggregation in ONS 15216 deployments. -
Vendor:Cisco
Cisco 15216-MD-48-CME | DWDM 48-ch Mux/Demux plug-in coupler/splitter, C-band, 100 GHz ITU-T grid, passive
15216-MD-48-CME
Stock Status: Enquire
Vendor:CiscoCisco 15216-MD-48-CME | DWDM 48-ch Mux/Demux plug-in coupler/splitter, C-band, 100 GHz ITU-T grid, passive
High-density 48-channel DWDM multiplexer/demultiplexer plug-in with integrated coupler/splitter for efficient wavelength aggregation in C-band networks using the ITU-T 100 GHz grid. Designed for ONS 15216 shelves, it is a passive, low-loss optical module ideal for metro, access, and backbone applications where space and flexibility matter. -
Vendor:Cisco
Cisco 15216-MD-48-CM | DWDM Mux/Demux 48‑ch C‑band | 100 GHz grid | Interleaver | LC connectors | Plug‑in module
15216-MD-48-CM
Stock Status: Enquire
Vendor:CiscoCisco 15216-MD-48-CM | DWDM Mux/Demux 48‑ch C‑band | 100 GHz grid | Interleaver | LC connectors | Plug‑in module
Passive plug‑in DWDM mux/demux and de‑interleaver module for high‑density wavelength aggregation in optical transport networks. Delivers C‑band channelization on a 100 GHz grid with low‑loss LC connectivity for OTN/SONET/ETH transport. -
Vendor:Cisco
Cisco 15216-HD-EXT-PNL | 1RU 4-Slot Mechanical Frame, HD Modules, Front-Access, 19-inch Rack
15216-HD-EXT-PNL
Stock Status: Enquire
Vendor:CiscoCisco 15216-HD-EXT-PNL | 1RU 4-Slot Mechanical Frame, HD Modules, Front-Access, 19-inch Rack
Compact 1RU mechanical frame providing four high-density module slots for passive optical filters such as mux/demux, OADM, and OSC. Front-access design simplifies installation and service in space-constrained racks. -
Vendor:Cisco
Cisco 15216-FLD-OSC | OSC Add/Drop Module, 1510 nm, LC, Passive, HD Slot
15216-FLD-OSC
Stock Status: Enquire
Vendor:CiscoCisco 15216-FLD-OSC | OSC Add/Drop Module, 1510 nm, LC, Passive, HD Slot
Edge Optical Service Channel add/drop filter for extracting and inserting the OSC used for out-of-band management and supervision in DWDM networks. Passive LC interface module designed for high-density frames. -
Vendor:Cisco
Cisco 15216-DCU-SA | Chassis: 2-slot DCM shelf, 19-inch rack, 1RU, passive mechanical housing; Optics support: LC/UPC DCM modules
15216-DCU-SA
Stock Status: Enquire
Vendor:CiscoCisco 15216-DCU-SA | Chassis: 2-slot DCM shelf, 19-inch rack, 1RU, passive mechanical housing; Optics support: LC/UPC DCM modules
Mechanical shelf assembly designed to house up to two dispersion compensation modules (DCMs) for streamlined, secure rack integration. Provides cable management and stable alignment for passive optical modules in DWDM transport networks. -
Vendor:Cisco
Cisco 15216-ATT-LC-7 | Optics: multi-rate up to 400G, Inline attenuator 7 dB, SMF (G.652/G.655), 1260–1620 nm, N/A reach, LC/UPC
15216-ATT-LC-7
Stock Status: Enquire
Vendor:CiscoCisco 15216-ATT-LC-7 | Optics: multi-rate up to 400G, Inline attenuator 7 dB, SMF (G.652/G.655), 1260–1620 nm, N/A reach, LC/UPC
Fixed optical attenuator for single-mode links requiring precise 7 dB loss, ideal for DWDM/CWDM power leveling, receiver protection, and lab/test environments. Low-reflection LC/UPC interfaces and broad 1260–1620 nm operating range ensure multi-rate compatibility across legacy and high-speed optics.
Why Choose XS Network Tech?
We are a trusted partner for businesses of all sizes, including government departments, data centres, and service providers. Our expert team in sales, logistics, and customer service ensures that your needs are met with speed and precision, from pre-sales consultation to order fulfilment. With a commitment to fast delivery, sustainability, and a wide inventory, XS Network Tech is your go-to source for IT hardware. Trust us for quality, fast responses, and a hassle-free experience every time.