-
Vendor:NVIDIA
NVIDIA 980-9I56Q-00N030 | Up to 400G | MPO-12 trunk | OS2 SMF 9/125 | DR4/PSM4 1310nm | 30m | 2x MPO | Yellow
980-9I56Q-00N030
Vendor:NVIDIANVIDIA 980-9I56Q-00N030 | Up to 400G | MPO-12 trunk | OS2 SMF 9/125 | DR4/PSM4 1310nm | 30m | 2x MPO | Yellow
High-density parallel‑optics MPO-12 trunk built on OS2 9/125 µm bend‑insensitive single‑mode fiber for DR4/PSM4 links up to 400G. Low‑loss, factory‑terminated MPO connectors preserve link budgets at 1310 nm across leaf/spine fabrics, panels, or direct transceiver runs. 30 m length with Type‑B polarity and yellow jacket enables plug‑and‑play integration for modern data center and InfiniBand/Ethernet parallel‑optic deployments. -
Vendor:NVIDIA
NVIDIA 980-9I56P-00N020 | MPO-12 trunk | 100/200/400G PSM4/DR4 compatible | 1310 nm SMF | 20 m | 2x MPO-12
980-9I56P-00N020
Vendor:NVIDIANVIDIA 980-9I56P-00N020 | MPO-12 trunk | 100/200/400G PSM4/DR4 compatible | 1310 nm SMF | 20 m | 2x MPO-12
20 m MPO‑12 OS2 single‑mode trunk for 1310 nm parallel‑optics links. Designed for DR4/PSM4‑class transceivers in dense fabrics, it enables reliable high‑throughput interconnects between switches, servers, and patch fields with low lane‑to‑lane skew. -
Vendor:NVIDIA
NVIDIA 980-9I56O-00N015 | MPO-12 trunk | 100/200/400G PSM4/DR4 compatible | 1310 nm SMF | 15 m | 2x MPO-12
980-9I56O-00N015
Vendor:NVIDIANVIDIA 980-9I56O-00N015 | MPO-12 trunk | 100/200/400G PSM4/DR4 compatible | 1310 nm SMF | 15 m | 2x MPO-12
MPO‑12 OS2 single‑mode trunk cable for parallel‑optics fabrics at 1310 nm. The 15 m yellow jacket assembly supports DR4/PSM4‑class transceivers for high‑speed Ethernet and InfiniBand, delivering low skew and consistent performance for structured cabling or direct device links. -
Vendor:NVIDIA
NVIDIA 980-9I559-00N002 | MPO-12 trunk | 100/200/400G PSM4/DR4 compatible | 1310 nm SMF | 2 m | 2x MPO-12
980-9I559-00N002
Vendor:NVIDIANVIDIA 980-9I559-00N002 | MPO-12 trunk | 100/200/400G PSM4/DR4 compatible | 1310 nm SMF | 2 m | 2x MPO-12
Short 2 m MPO‑12 single‑mode trunk for parallel‑optics connections using 1310 nm optics such as PSM4/DR4. The yellow jacket OS2 assembly enables high‑bandwidth interconnects between devices or patch panels in dense fabrics, delivering low skew and consistent performance across all 12 fibers. -
Vendor:NVIDIA
NVIDIA 980-9I530-00W000 | Mellanox Select 400GbE QSFP-DD SR8 Transceiver
980-9I530-00W000
Vendor:NVIDIANVIDIA 980-9I530-00W000 | Mellanox Select 400GbE QSFP-DD SR8 Transceiver
Pluggable optical transceiver for NVIDIA networking platforms. Use the platform bill of materials or compatibility matrix to confirm the exact form factor, data rate, optical standard, wavelength, reach, and connector for this part reference. -
Vendor:NVIDIA
NVIDIA 980-9I46U-00N02A | OSFP AOC, 400G InfiniBand NDR/400GbE, OM4 MMF 850nm, 2.5 m, OSFP–OSFP
980-9I46U-00N02A
Vendor:NVIDIANVIDIA 980-9I46U-00N02A | OSFP AOC, 400G InfiniBand NDR/400GbE, OM4 MMF 850nm, 2.5 m, OSFP–OSFP
Active optical cable for InfiniBand NDR and 400GbE OSFP ports. The 2.5 m reach suits top-of-rack to nearby rack connections while maintaining low latency and high signal integrity. -
Vendor:NVIDIA
NVIDIA 980-9I46I-00N01A | 400G OSFP AOC Breakout | IB NDR | 850nm | 1.5 m | OSFP–4xOSFP
980-9I46I-00N01A
Vendor:NVIDIANVIDIA 980-9I46I-00N01A | 400G OSFP AOC Breakout | IB NDR | 850nm | 1.5 m | OSFP–4xOSFP
High-performance OSFP active optical breakout for NDR fabrics. It fans out a high-speed OSFP link into four OSFP legs over 1.5 meters, using 850 nm multimode optics for low-latency, low-EMI intra-rack connectivity. -
Vendor:NVIDIA
NVIDIA 980-9I433-00N001 | Optics: 400G, OSFP AOC (FLAT), IB NDR/400GbE, 850nm, 1m, OSFP↔OSFP
980-9I433-00N001
Vendor:NVIDIANVIDIA 980-9I433-00N001 | Optics: 400G, OSFP AOC (FLAT), IB NDR/400GbE, 850nm, 1m, OSFP↔OSFP
Flat‑jacket OSFP active optical cable designed for ultra‑dense routing and tight cable management in 400G fabrics. Delivers the same low‑power, EMI‑immune performance as standard AOCs with a low‑profile, lay‑flat construction that eases dressing through congested pathways and narrow rack gaps. -
Vendor:NVIDIA
NVIDIA 980-9I432-00N001 | Optics: 400G, OSFP AOC, IB NDR/400GbE, 850nm, 1m, OSFP↔OSFP
980-9I432-00N001
Vendor:NVIDIANVIDIA 980-9I432-00N001 | Optics: 400G, OSFP AOC, IB NDR/400GbE, 850nm, 1m, OSFP↔OSFP
High‑bandwidth OSFP active optical cable for 400G InfiniBand NDR and 400GbE platforms. The integrated transceiver‑cable assembly delivers lightweight, low‑power, EMI‑immune links with consistent performance and simplified deployment. Ideal for short‑reach switch‑to‑switch or switch‑to‑adapter connections in dense fabrics. -
Vendor:NVIDIA
NVIDIA 980-9I08S-00W050 | 400G QSFP-DD AOC | 850 nm MMF | 50 m | QSFP-DD to QSFP-DD
980-9I08S-00W050
Vendor:NVIDIANVIDIA 980-9I08S-00W050 | 400G QSFP-DD AOC | 850 nm MMF | 50 m | QSFP-DD to QSFP-DD
High-bandwidth active optical cable for short-reach 400G interconnects. QSFP‑DD connectors on both ends deliver 8x50G PAM4 lanes over multimode fiber at 850 nm. Ideal for switch-to-switch or switch-to-adapter links where low weight, tight bend radius, and EMI immunity are required. Blue pull-tabs provide quick identification and easy extraction. -
Vendor:NVIDIA
NVIDIA 980-9I08Q-00W020 | QSFP-DD 400G AOC | 8x50G PAM4 | 850nm MMF | 20m reach | QSFP-DD to QSFP-DD
980-9I08Q-00W020
Vendor:NVIDIANVIDIA 980-9I08Q-00W020 | QSFP-DD 400G AOC | 8x50G PAM4 | 850nm MMF | 20m reach | QSFP-DD to QSFP-DD
20‑meter 400G active optical cable for extended short‑reach interconnects across rows or between racks. The QSFP‑DD AOC integrates optics and multimode fiber to provide stable 8x50G PAM4 signaling at 850nm, delivering low power, low EMI, and streamlined installation compared with discrete optics plus patch cords. -
Vendor:NVIDIA
NVIDIA 980-9I08M-00W005 | QSFP-DD 400G AOC | 8x50G PAM4 | 850nm MMF | 5m reach | QSFP-DD to QSFP-DD
980-9I08M-00W005
Vendor:NVIDIANVIDIA 980-9I08M-00W005 | QSFP-DD 400G AOC | 8x50G PAM4 | 850nm MMF | 5m reach | QSFP-DD to QSFP-DD
400G active optical cable for short‑reach switch and server interconnects. The QSFP‑DD to QSFP‑DD AOC integrates optics and multimode fiber, providing predictable latency, reduced EMI, and simplified deployment compared to discrete transceivers and patch cords. Suited for high‑density 400GbE fabrics and scalable spine/leaf architectures. -
Vendor:NVIDIA
NVIDIA 980-9I08O-00W010 | QSFP-DD 400G AOC | 8x50G PAM4 | 850nm MMF | 10m reach | QSFP-DD to QSFP-DD
980-9I08O-00W010
Vendor:NVIDIANVIDIA 980-9I08O-00W010 | QSFP-DD 400G AOC | 8x50G PAM4 | 850nm MMF | 10m reach | QSFP-DD to QSFP-DD
10‑meter 400G QSFP‑DD active optical cable designed for flexible rack‑to‑rack or row deployments. Delivers consistent latency and signal integrity using 8x50G PAM4 lanes over integrated multimode fiber at 850nm, minimizing EMI and simplifying installation in high‑density environments. -
Vendor:NVIDIA
NVIDIA 980-9I08K-00W003 | QSFP-DD 400G AOC | 8x50G PAM4 | 850nm MMF | 3m reach | QSFP-DD to QSFP-DD
980-9I08K-00W003
Vendor:NVIDIANVIDIA 980-9I08K-00W003 | QSFP-DD 400G AOC | 8x50G PAM4 | 850nm MMF | 3m reach | QSFP-DD to QSFP-DD
High-density 400G active optical cable for leaf–spine and server uplinks. The integrated QSFP‑DD to QSFP‑DD AOC uses 8x50G PAM4 lanes over multimode fiber at 850nm to deliver predictable, low‑latency performance in congested racks and rows. Factory-terminated optics simplify deployment, reduce EMI versus copper, and eliminate fiber cleaning/inspection associated with pluggable transceivers and patch cords. Ideal for short‑reach 400GbE switch-to-switch or switch-to-adapter connections in modern data centers. -
Vendor:Juniper
Juniper QFX5130-32CD-D-AFO | 32x400G QSFP-DD | 1U DC | airflow port-intake/PSU-exhaust (AFO) | Trident 4 | PoE: none | license: base
QFX5130-32CD-D-AFO
Vendor:JuniperJuniper QFX5130-32CD-D-AFO | 32x400G QSFP-DD | 1U DC | airflow port-intake/PSU-exhaust (AFO) | Trident 4 | PoE: none | license: base
High-density 1U 32x400GbE QSFP-DD switch with DC power and AFO airflow (port side intake, PSU side exhaust). Optimized for front-to-back cooling layouts, enabling 400G or 4x100G breakouts per port on Broadcom Trident 4. -
Vendor:Juniper
Juniper QFX5130-32CD-D-AFI | 32x400G QSFP-DD | 1U DC | airflow PSU-intake/port-exhaust (AFI) | Trident 4 | PoE: none | license: base
QFX5130-32CD-D-AFI
Vendor:JuniperJuniper QFX5130-32CD-D-AFI | 32x400G QSFP-DD | 1U DC | airflow PSU-intake/port-exhaust (AFI) | Trident 4 | PoE: none | license: base
High-density 1U 32x400GbE QSFP-DD switch with DC power and AFI airflow (PSU side intake, port side exhaust). Suited for spine/leaf roles, offering 400G or 4x100G breakouts per port on Broadcom Trident 4 silicon.
Why Choose XS Network Tech?
We are a trusted partner for businesses of all sizes, including government departments, data centres, and service providers. Our expert team in sales, logistics, and customer service ensures that your needs are met with speed and precision, from pre-sales consultation to order fulfilment. With a commitment to fast delivery, sustainability, and a wide inventory, XS Network Tech is your go-to source for IT hardware. Trust us for quality, fast responses, and a hassle-free experience every time.