The UCSC-PSU2-1400 is a 1400 W AC hot-plug power supply module for Cisco UCS C-Series 2U and 4U rack servers. It suits redundant or high-capacity power in data-centre racks running virtualisation, HyperFlex and compute-intensive workloads, and it supports 1+1 redundant power configurations in dual-PSU servers.

This 1400W AC, 200-240V version is the original (V1, non-V2) part. It delivers up to 1400 W at 200-240 VAC input, with 12 VDC main and 12 VDC standby outputs. Nominal input is 200-240 VAC at 50 or 60 Hz, with a maximum input current of 8.5 A at 200 VAC and a maximum of 1700 VA. It is 80Plus Platinum certified, reducing wasted power in always-on server environments, and connects through an IEC60320 C14 inlet.

It works with Cisco UCS 2U and 4U C-Series rack servers such as the C240 M4 and C460 M4, as well as HyperFlex HX240c nodes. As a hot-pluggable, field-replaceable RSP1 module, a unit can be swapped without taking the server offline when installed in a redundant pair.

Enquire with XS Network Tech for new or used pricing and availability.

Features

- Hot-pluggable, field-replaceable power supply module
- Supports 1+1 redundant power configurations in dual-PSU servers
- 80Plus Platinum efficiency for lower power waste
- Supports Cisco UCS 2U and 4U C-Series rack servers
- High-line 200-240 V AC operation
- RSP1 form factor with IEC60320 C14 inlet

Warranty

All products sold by XS Network Tech include a 12-month warranty on both new and used items. Our in-house technical team thoroughly tests used hardware prior to sale to ensure enterprise-grade reliability.

All technical data should be verified on the manufacturer data sheets.

View full details

specs-tabs

Collapsible content

Technical Specifications

FAQs

Technical Specifications

- Maximum output power: 1400 W at 200-240 VAC
- AC input voltage: 200-240 VAC nominal (180-264 VAC range)
- AC input frequency: 50 to 60 Hz (47-63 Hz range)
- Maximum AC input current: 8.5 A at 200 VAC
- Maximum input volt-amperes: 1700 VA
- Maximum inrush current: less than 30 A at 25 C (sub-cycle duration)
- Maximum hold-up time: 12 ms at 1200 W
- Output voltage: 12 VDC
- Standby voltage: 12 VDC
- Efficiency rating: 80Plus Platinum, Climate Savers Platinum
- Form factor: RSP1
- Input connector: IEC60320 C14
- Hot-plug: Yes

FAQs

Q: Can this power supply run from 110 V mains?
A: No. This 1400 W module is specified for high-line input of 200-240 VAC (180-264 VAC range) and delivers its full 1400 W output in that range.

Q: Which servers does it work with?
A: It is used in Cisco UCS 2U and 4U C-Series rack servers, including the C240 M4 and C460 M4, and HyperFlex HX240c nodes.

Q: What input connector and current should I plan for?
A: The power supply uses an IEC60320 C14 inlet. Maximum input current is 8.5 A at 200 VAC, with a maximum of 1700 VA.

Q: How does this differ from the V2 version?
A: This is the original 1400W AC, 200-240V part (V1, non-V2). Cisco also lists a later V2 part, UCSC-PSU2V2-1400W, as a separate part number.

Q: Can I run two of these for redundancy?
A: Yes. It supports 1+1 redundant configurations in servers with dual power supply bays, and as a hot-plug unit it can be swapped without powering the server down.

Recently Viewed

  • Request a Quote

    Looking for competitive pricing? Submit a request, and our team will provide a tailored quote that fits your needs.

  • Contact Us Directly

    Have a question or need immediate assistance? Call us for expert advice and real-time support.

    Call us Now  
  • Contact Us Directly

    Have a question or need immediate assistance? Call us for expert advice and real-time support.

    Contact us