This is a 1000W AC-input internal power supply for the Cisco Catalyst 4900M data-centre switch. It suits data-centre top-of-rack switching and midmarket collapsed core or aggregation deployments built on the Catalyst 4900M, providing either primary or redundant AC power.

The supply delivers 960W of output at 12 VDC, up to 80 A, from a 100-240 VAC, 50-60 Hz input. Maximum input current is 12 A at 100 VAC and 5 A at 240 VAC. It is hot-swappable and field-replaceable, supports 1+1 redundancy, and the switch can run on a single supply. With two installed, the load is shared. Each supply monitors its own temperature and output voltages, and the switch reports status through software. This is the 1000W AC spare unit, while PWR-C49M-1000AC/2 is the redundant second unit.

It is designed for the Catalyst 4900M, which has two power supply bays. The 1000W DC supply (PWR-C49M-1000DC) is the DC alternative, and AC and DC supplies are interchangeable in the chassis. No licence or subscription is required.

Enquire with XS Network Tech for new or used pricing and availability.

Features

- 1+1 hot-swappable AC power supplies for high availability
- Switch can run on a single supply, with load sharing when two are installed
- Each supply monitors its own temperature and output voltages, with status reported through software
- Front-panel INPUT OK and OUTPUT OK LEDs, power on/off switch and captive installation screws
- Field-replaceable design extends hardware longevity
- In redundant mode, most power supplies can be replaced without powering down the switch

Warranty

All products sold by XS Network Tech include a 12-month warranty on both new and used items. Our in-house technical team thoroughly tests used hardware prior to sale to ensure enterprise-grade reliability.

All technical data should be verified on the manufacturer data sheets.

View full details

specs-tabs

Collapsible content

Technical Specifications

FAQs

Technical Specifications

- Power supply output: 960 W
- Rated capacity: 1000W AC-input supply
- Output voltage: 12 VDC
- Output current: 80 A maximum
- AC input voltage: 100-240 VAC
- AC input current: 12 A maximum at 100 VAC, 5 A maximum at 240 VAC
- AC frequency: 50 to 60 Hz
- Inrush value: cold turn on, 50 A for one cycle of AC
- Input rating: 1.200 KVA
- Power supply dissipation: 240 W
- Heat dissipation: 818.88 BTU/hr maximum
- Redundancy: 1+1 hot-swappable
- Weight: 2.0 kg (4.5 lb)
- Switch operating temperature: 0 to 40 C (32 to 104 F)
- Switch storage temperature: -40 to 75 C (-40 to 167 F)
- Switch relative humidity: 10 to 90 percent, non-condensing
- Switch operating altitude: -60 to 2000 m (-197 to 6562 ft)
- Minimum software: Cisco IOS Software Release 12.2(46)SG

FAQs

Q: Which switch does the PWR-C49M-1000AC fit?
A: It is for the Cisco Catalyst 4900M, which has two power supply bays. The Catalyst 4900M is supported only on Cisco IOS Software, minimum release 12.2(46)SG.

Q: Does the switch need two power supplies?
A: No. The Catalyst 4900M can run on a single supply. Installing a second supply gives 1+1 redundancy and the two share the load.

Q: Can I mix AC and DC power supplies in one chassis?
A: Yes. AC-input and DC-input supplies are interchangeable in the Catalyst 4900M chassis. The 1000W DC alternative is PWR-C49M-1000DC.

Q: What is the difference between PWR-C49M-1000AC and PWR-C49M-1000AC/2?
A: PWR-C49M-1000AC is the 1000W AC spare unit, while PWR-C49M-1000AC/2 is the redundant second unit for the same switch.

Q: Does this power supply need a licence?
A: No. No licence or subscription is required.

Q: Can it be replaced while the switch is running?
A: In redundant mode, most power supplies can be replaced without powering down the switch. The AC supply must be switched off and unplugged before it is removed or inserted.

Recently Viewed

  • Request a Quote

    Looking for competitive pricing? Submit a request, and our team will provide a tailored quote that fits your needs.

  • Contact Us Directly

    Have a question or need immediate assistance? Call us for expert advice and real-time support.

    Call us Now  
  • Contact Us Directly

    Have a question or need immediate assistance? Call us for expert advice and real-time support.

    Contact us