Cisco NXA-PDC-2KW-PI | DC PSU 2kW | PI airflow (back-to-front) | hot-swap, N+1 | for N9K/N3K

SKU:NXA-PDC-2KW-PI

Regular price POA
POA
POA
Sale Sold out
Taxes included. Shipping calculated at checkout.

Description

2000W hot-swappable DC power supply with port-side intake airflow (back-to-front) for select data center switches. Supports -48 to -60 VDC input and enables N+1 redundancy and load sharing when used with matching units. Ideal where back-to-front thermal direction is required to match rack design.

Features

- 2kW output for demanding configurations
- PI airflow supports back-to-front cooling strategies
- Hot-swap capable to minimize service interruption
- N+1 redundancy and load sharing
- Designed for -48 VDC data center and telco environments
- FRU module for quick field replacement

Warranty

All products sold by XS Network Tech include a 12-month warranty on both new and used items. Our in-house technical team thoroughly tests used hardware prior to sale to ensure enterprise-grade reliability.

All technical data should be verified on the manufacturer data sheets.

View full details

specs-tabs

Collapsible content

Technical Specifications

FAQs

Technical Specifications

- Output power: 2000 W
- Input type: DC (-48 to -60 VDC typical)
- Airflow: Port-side Intake (back-to-front)
- Hot-swappable: Yes
- Redundancy: N+1 with load sharing
- Form factor: Field-replaceable PSU module
- Compatibility: Select 9K/3K data center switches (verify per chassis)
- DC connection: Terminal/lug style (installer-provided cabling)

FAQs

Q: What does PI airflow mean?
A: PI (Port-side Intake) draws air in from the port side and exhausts toward the rear—back-to-front in most rack layouts.

Q: Can I mix PI and PE PSUs?
A: No. Use the same airflow type across all PSU slots for proper cooling and support compliance.

Q: Is it hot-swappable?
A: Yes, it can be replaced while the system is running when redundancy is present.

Q: How do I verify compatibility?
A: Check your switch model’s hardware installation guide for supported DC PSU part numbers and airflow orientation.

Q: What DC plant voltage is required?
A: Designed for -48 VDC systems; consult the hardware guide for the supported operating range and wiring requirements.

  • Related products

Recently Viewed

  • Request a Quote

    Looking for competitive pricing? Submit a request, and our team will provide a tailored quote that fits your needs.

  • Contact Us Directly

    Have a question or need immediate assistance? Call us for expert advice and real-time support.

    Call us Now  
  • Contact Us Directly

    Have a question or need immediate assistance? Call us for expert advice and real-time support.

    Contact us