Cisco NXA-PDC-1500W-PE | DC PSU 1500W | PE airflow (front-to-back) | hot-swap, N+1 | for N9K/N3K

SKU:NXA-PDC-1500W-PE

Regular price POA
POA
POA
Sale Sold out
Taxes included. Shipping calculated at checkout.

Description

1500W hot-swappable DC power supply with port-side exhaust airflow (front-to-back) for select data center switches. Supports -48 to -60 VDC input and enables N+1 redundancy and load sharing when deployed with matching units. Ideal for DC-powered racks and front-to-back thermal designs.

Features

- 1500W capacity for dense leaf/spine deployments
- Front-to-back (PE) airflow aligns with typical data center cooling
- Hot-swap design reduces maintenance downtime
- Supports N+1 redundancy and load sharing for higher availability
- DC input suits telco and DC-powered facilities
- Field-replaceable FRU simplifies service operations

Warranty

All products sold by XS Network Tech include a 12-month warranty on both new and used items. Our in-house technical team thoroughly tests used hardware prior to sale to ensure enterprise-grade reliability.

All technical data should be verified on the manufacturer data sheets.

View full details

specs-tabs

Collapsible content

Technical Specifications

FAQs

Technical Specifications

- Output power: 1500 W
- Input type: DC (-48 to -60 VDC typical)
- Airflow: Port-side Exhaust (front-to-back)
- Hot-swappable: Yes
- Redundancy: N+1 with load sharing (when paired with matching PSUs)
- Form factor: Field-replaceable PSU module
- Compatibility: Select 9K/3K data center switches (verify per chassis)
- DC connection: Terminal/lug style (installer-provided cabling)

FAQs

Q: What does PE airflow mean?
A: PE (Port-side Exhaust) moves air from the port side toward the power/IO side—front-to-back in most racks.

Q: Can I mix this DC PSU with AC PSUs in the same switch?
A: Mixing AC and DC supplies is not supported on most platforms. Use the same type, wattage, and airflow per the switch hardware guide.

Q: Is it hot-swappable?
A: Yes. It can be replaced without powering down when installed in a supported redundant configuration.

Q: Which switches is it compatible with?
A: Select 9K/3K data center switches. Check your exact chassis model’s hardware installation guide for supported PSU part numbers.

Q: What DC wiring is required?
A: It uses terminal/lug connections to a -48 VDC plant. Conductor size, fuse/breaker ratings, and polarity must follow the switch installation guide and local code.

  • Related products

Recently Viewed

  • Request a Quote

    Looking for competitive pricing? Submit a request, and our team will provide a tailored quote that fits your needs.

  • Contact Us Directly

    Have a question or need immediate assistance? Call us for expert advice and real-time support.

    Call us Now  
  • Contact Us Directly

    Have a question or need immediate assistance? Call us for expert advice and real-time support.

    Contact us